Focusing on Measuring, Monitoring and Control of Current, Voltage

Power and Energy

Split core Single phase DC multi-parameter transducer GS-DP1B0-GxPD

Split core Single phase DC multi-parameter transducer GS-DP1B0-GxPD

Model
GS-DP1B0-GxPD
Input Range
Power Supply
Output
Mounting
Size
Split core Single phase DC Multi-Parameter transducer, Model  GS-DP1B0-GxPD

 

Overview

This model GS-DP1B0-GxPD is a split core DC multi-parameter transducer. It can measure parameters of current,voltage,power, frequency, and energy etc  Processing by advanced MCU and precisive 24-digit AD Converter, this transducer has the advantages of high precision,stability,anti-interference and superior performance. the RS-485 output,supporting Modbus-RTU protocol,is fully compatible with a variety of configuration software or PLC.; It has been widely used in electricity, communications, railways, industrial control and many other fields.


Feature

  • Measuring multi-parameter:current,voltage, power, frequency,and energy (KWH);
  • Available with wide power supply: DC: 10-30V or 10-55V
  • Easy to operate and installation;Can be bipolar measurement, with positive and negative active power and cumulative energy measurement function.The intelligent transducer with the smallest size and wide current measurement range in the peer.
  • Energy has positive and negative cumulative function, with power-down storage.With red and green light-emitting diode instructions function, the red light indicates the normal operation of the product (100mS flashing), the green light indicates the product communication.
  • High anti-interference ability, the input, output and power port to resist the surge voltage up to 2KV or more.

Specification

NO.

Item

Date

Unite

Remarks

1

Accuracy

1.0

%

 

Input range

1000V*1000A;

   

2

Baud rate

19.2K9600(default),   4800, 2400, 1200

bps

Factory default communication format:   9600, N / 8/1, address 1

Communication

RS-485(twisted pair line) , RS-232C(treble   line, only for N style parts)

 

RS422 optional

Parity

None, Even, Odd, Space

   

Max. number of nodes

64

node

Only for RS-485

Bus protection

400W transient voltage

 

ESD protection and thermosnap

3

A/D SPEED

100

mS

 

4

Working temperature

-20~+60

   

5

Isolation voltage

Input/output:   2500V DC for 1 min

Input/power supply2500V   for 1 min

Output/power supply2500V   for 1 min

 

V

 

The double isolation part numbers, their   output and power supply are grounded together , there is only between the input and output   isolation voltage

6

Overload

2 x voltage span 1   sec. 10 for times with interval of 10 sec.

10 x current span   for 1 sec. 5 times with an interval of 300 sec (only for hole thru. parts)

 

The input outside the linear range will   result in poor accuracy

7

MTBF

>30000

hour

 

8

Auxiliary power supply

+5V/+12V/+24V/+48V/ AC220V

V

220VAC,DC only for N case parts

9

Power consumption

≤250mW(+12V)≤500mW(+24V)

mW

Power consumption depends on power supply   to be used

10

Temperature drift

≤300

ppm/

 (-20℃~+60℃)

 

Size and Diagram

 

                     

 

          


                         

Online message