AC Power Transducer

Home < Products < AC Power Transducer < Digital AC Power Transducer

Digital AC Power Transducer

  • 0.5A~30A AC,20V~750V AC, Digital  3Phase 3Wire AC Power Transducer (3-wattmeter method)
  • 0.5A~30A AC,20V~750V AC, Digital  3Phase 3Wire AC Power Transducer (3-wattmeter method)
  • 0.5A~30A AC,20V~750V AC, Digital  3Phase 3Wire AC Power Transducer (3-wattmeter method)
  • 0.5A~30A AC,20V~750V AC, Digital  3Phase 3Wire AC Power Transducer (3-wattmeter method)

0.5A~30A AC,20V~750V AC, Digital 3Phase 3Wire AC Power Transducer (3-wattmeter method)

contact us
share to:
  • Features
  • Download

Digital 3Phase 3Wire AC Power Transducer measuring voltage 20V~750V AC,current 0.5A~30A AC, with RS485 Output (3-wattmeter method)

 
Overview            
            GS-AP3B1-GxEC series (3-wattmeter method) is a digital 3phase 3wire AC power transducer with RS485 output.This digital power transducer is designed for complete monitoring of electrical power systems. This digital power transducer can measure voltage, current, active power, reactive power,apparent power, power factor,frequency and energy in the electric power system and these measured data can be streamed over an RS485 interface to  PLC or other data acquisiton devices. With the advanced MCU and precisive 24-digit AD Converter in-built, this digital transducer has the advantages of high precision and superior performance. The measuring range of the power transducer is voltage 20V~750V AC,0.5A~30A AC;
 
Specifications:
* Accuracy:Class 0.5
* Power Supply:12V-24VDC(Wide-range power supply)
* Frequency:40~75Hz
* Input Range:Voltage:20V~750V AC;Current:AC0.5A~30A AC;(Customizable)
* Voltage Impedance:≥1.2KΩ/V
* Output:RS-485、RS-232(Optional)
* Communications Protocol:MODBUS_RTU
* Operating Temperature:-10℃~+60℃
* Baudrate:1200、2400、4800、9600(default)、19200、38400、57600bps
* Data Format:“n,8,1”(default)、“n,8,2”、“e,8,1”、“o,8,1”
* RS485 Communications Nodes:64 (Maximum);
* Static Power Consumptions:≤0.5W
* Rated Power Consumptions:≤0.5W
* Load of Isolation Voltage:DC 2500V
* Response Time:≤300ms(default 100ms)
* Thermal Drift:≤300PPm/℃
* Lightning Surge Immunity:Power-supply end 2000V,Input end 2000V,Output end 500V
* Case Style:E
* Case Material:ABS (Flame retardancy, UL94-V0)
* Mounting: 35mm DIN rail or screw;

Wiring diagram

0.5A~30A AC,20V~750V AC, Digital  3Phase 3Wire AC Power Transducer (3-wattmeter method)(图1)
Current input thru aperture; Terminal 4,5 and 6 for voltage input; Terminal 7 and 8 for output;Terminal 10 and 11 for power supply;